Facilities
Data
Center Overview
Our Co Location network
center has been designed to accommodate clients demanding
the highest quality network performance. There is a central
focus on redundancy allowing our network to rapidly
self-heal failures without interruptions to connectivity.
Tier-1 Premium Bandwidth
Providing the highest quality
Internet connectivity and performance is our top priority.
Co Location network center
has selected premium Tier-1 bandwidth providers, ensuring
minimal latency and fast connections to all points of the
global internet. We are proud to feature direct connectivity
with MCI, AT&T, Savvis and Level3. Our aggregate
connectivity reaches an astounding 4,500+ networks just a
single network away from our uplinks.
On-Site Security
Our Co
Location network center
access is strictly limited to
technical staff. Electronic security systems control data
center access and are accompanied by a full compliment of
motion detecting security cameras which monitor the entire
facility. Our Co Location facility external walls are
reinforced poured concrete. We are housed in a fully
managed facility, which means we have level 3 technicians on
site 24 hours per day, allowing incident response times to
be kept to a minimum.
Power System
Our Co
Location network center
power systems feature extensive fault tolerance and
resilience at every layer. Incoming service is routed
underground to a dedicated on-site transformer. This system
routes to our automatic transfer switch which monitors power
quality, and automatically transfers to our emergency
generators in the event they are needed. Each facility is
also protected by one or more Uninteruptable Power Supplies
(UPS), featuring redundant battery cabinets and full
maintenance bypass cabinets allowing for service and
upgrades without interruption of power to our servers.
Liebert Precision power distribution units handle final
power transformation and distribution to racks, ensuring
clean consistent power to data center equipment.
Our Co Location network
center facility has multiple emergency generators waiting on
standby, featuring over 24 hours of autonomous runtime
before requiring refueling. Each generator is test run at
least once a week to ensure they are ready in the event they
are needed.
Generator power is
activated automatically in the event of a utility failure by
the transfer switch. The data center load is maintained by
the UPS units with at least 15 minutes of capacity, however
this is not necessary as the generator is active and up to
speed within 10 seconds of a power failure.
|